Page view 16
If overheating occurs, be sure
to correct the cause before
continuing to use the 3-Phase
Power Supply.
Once the unit has cooled the unit will revert to the
green “Standby” condition. To restore the unit to
the blue “Operate” mode, simply press the front
panel button.
Status LED Summary
Red Warmup / Brownout – The low-distortion
oscillator is stabilizing after the unit is first powered
on. The indicator will also glow red if the AC line
voltage drops below about 80% of normal.
Green Standby – The power supply is ready to enter
“Operate” mode.
Blue Operate (33-
1
/3 rpm) – The turntable is running at
33-
1
/3 rpm.
Violet Operate (45 rpm) – The turntable is running at 45
rpm.
Orange Over Temperature – The motor-drive amplifiers
has exceeded their safe operating temperatures due
to poor ventilation. The unit will automatically
revert to “Standby” (green) when it has cooled. Be
sure to correct the problem before continuing to use
the power supply.
Flashing Violet Configuration Mode – The unit has been placed
into the “Configuration Mode”. Please refer to the
chapter “Optimization and Customization” for
additional details. It will automatically revert to
“Standby” (green) after ten seconds.